Leak stop super seal total 2 seals ac/r leaks & more


CLIPLIGHT COMPANY, simplifing A/C and Refrigeration repair
"THE NEW APPROACH FOR HARD TO FIND MICRO LEAKS"
FOR RESIDENTIAL UNITS 1.5 TON or 5.3 KW and up to 5 TON.
One 3 fl oz can for systems 1.5 ton up to 5 tons.
Two 3 fl oz cans for systems greater than 5 ton and up to 25 ton.
Use only on low-pressure side.
REPAIRS HARD TO FIND LEAKS AND CONTINUES TO CIRCULATE IN THE SYSTEM TO SEAL FUTURE LEAKS.
For professional use only: Always wear safety glasses and protective gloves
* Super Seal TOTAL 2 permanently seals micro leaks in condensers, evaporators, and lines in A/C and Refrigeration systems.
* Contains a drying agent which eliminates moisture while increasing drier efficiency, also prevents acid from forming and contains UV tracer dye to find larger leaks.
* Seals hard to find micro leaks
* Compatible with ALL oils and refrigerants
* For use in systems 1.5 TON or larger and 30 oz. oil capacity in sump.
* Perfect for Residential Commercial or Industrial applications
* IDEAL FOR DRYING WET SYSTEMS AND SEALING MICRO LEAKS CAUSED BY FORMICARY & ACID CORROSION.
* Ideal for leaks caused my formicary (ants nest) & internal acid corrosion, vibration, and temperature variation.
* Complete one time use throw away kit
For professional use only: Always wear safety glasses and protective gloves
Always point can bottom away from yourself when charging or injecting - Can bottom has a pressure relief valve which will release if pressure exceeds 300 Psig / 2068 KPa
The system should be fully charged before injecting
One 3 fl oz / 89 ml can for systems 1.5 ton / 5.3 KW up to 5 ton / 17.6 KW
Two 3 fl oz / 89 ml cans for systems greater than 5 ton / 17.6 KW and up to 25 ton / 88KW
INSTRUCTIONS: clock wise = cw and counter clockwise = ccw.
1. Turn off A/C unit and allow enough time for refrigerant to equalize in system.
2. Confirm that can tapper piercing pin (B) is fully retracted below seating washer. Turn valve handle (A) ccw.
3. Thread SUPER SEAL TOTAL can (C) onto can-tapper (B) by turning cw. Be careful not to cross thread or over tighten.
4. Thread female fitting (D) onto vacuum pump and draw vacuum for approximately 1 minute to eliminate air in tap hose. (Where Regional and Federal laws permit you may use systems refrigerant to purge hose. Connect hose to low side charging port while unit is off and back off can from tapping valve allowing refrigerant up to the tapping valve can assembly. Skip to step 7.
5. Remove female fitting (D) from vacuum pump while it is running to maintain vacuum in tap hose. After disconnecting shut down vacuum pump.
6. Thread female fitting (D) onto low side service port immediately after removing from vacuum pump.
7. Turn can-tapper piercing handle (A) cw until it stops. This action pierces the can.
9. Turn handle (A) cw until it stops, isolating charged can from A/C or R unit.
11. Once can is empty remove female fitting (D) from low side service port, while the unit is running.
12. Reclaim residual refrigerant from can and hose using a recovery machine. When finished reclaiming refrigerant, dispose of can and hose.
TAPPING VALVE AND HOSE NOT TO BE REUSED.