____________________   >   Auburn   >   System components   >   Old Style   >   Beckman mdq capillary electrophoresis system with pda

Beckman mdq capillary electrophoresis system with pda


Beckman MDQ with PDA Just serviced by Beckman comes with computer and LCD monitor and acessories.
Description: The P/ACE Series are automated, programmable capillary electrophoresis systems designed to perform fast separations from complex samples. Separations occur in a capillary which is housed in an interchangeable cartridge with circulating liquid coolant for efficient temperature control. This finely regulated temperature control allows the use of high-ionic-strength buffers and large-bore capillaries necessary for analyzing difficult samples. With CE, methods are faster to develop, easier to validate, and less expensive to run. However, specialized system designs are required to optimize performance for different applications.
Comes with LIF Module. With computer and data system(software). Sample Cooling.
-Sample Introduction - Pressure, Vacuum, Electrokinetic
-Pressure Range - -5 to +100 psig (Rinse/Separations), -5 to +25 psig (Sample Introduction)
-Capillary Cartridge - Recirculating liquid coolant 15 to 60C
-Data Rate Collection - 0.5 to 32 Hz
-Scan Collection - Diode Array 0.5 - 32 Hz (user selected)
-Buffer Tray - 61 x 36 2 mL vials, 4 x 25 mL trays
-Height - 68.90 cm (27.13 in); with Door Open 92.70 cm (36.5 in)
-Modes of Operation - Constant/Gradient Voltage, Current, and Power. Variable pressure
-Sample Tray - 61 x 96-well plates, 2 x 48 2 mL vials, 2 x 48 0.5 mL vials, 2 x 48 PCR vials
-Current Range - 62 - 300 Amps
-Weight - 60 kg (132 lb) without sample cooling option, 70.5 kg (155 lb) with sample cooling option (uncrated)
-Electrical Requirements - Voltage 90 - 240 V 50/60 Hz
-Voltage Range - 60 - 30 kV (1 - 10 kV for injections), Programmable in 0.1 kV increments, Reversible voltage programmed through user interface.
-Wavelength Range - Diode Array 190 - 600 nm, UV/Vis 200, 214, 254, 280 nm standard filter, 190 - 600 nm (with custom filter options)
-Optional Detectors - Diode Array, Laser-Induced Fluorescence
Environment Sample temperature environment is independent of the ambient buffer environment (ambient is defined as 25C)



Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda Beckman mdq capillary electrophoresis system with pda