Universal replacement hot surface ignition module S8910
Honeywell S8910U1000 universal hot surface ignition module. Replaces Honeywell S89 and S890 series; White-Rodgers 50E47 and 50F47 series and Robertshaw 780 series modules. S8910U1000Product Specifications Ignition System Type Direct Hot Surface Ignition Ignition Sequence The number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial. Flame Sense One Rod/Two Rods Ignition Source Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270) Prepurge (sec) 32 sec Ignition Trials To Lockout 1 or 3 Lockout Timing 4 sec or 7 sec Ignition Trial Time (sec) 4 sec or 7 sec Between Trial Time (sec) (2) 96 sec- 3 trial mode only Maximum Valve Load @ 24 Vac (Amps) 2A Flame Failure Response Time (sec) 1.5 sec Typical Ignition Hardware Norton 201, Norton 271, Q354 Typical Gas Control VR8205, VR8305 Gas Type LP/Natural Approvals CSA Design Certified Description Provide electronic control of direct hot surface ignition systems used on gas fired furnaces, boilers, and other heating appliances. Dimensions (in.) 5 1/4 in. high, 4 1/16 in. wide, 1 15/16 in. long Dimensions (mm) 133 mm high, 103 mm wide, 49 mm deep Control Voltage (Thermostat or other call for heat) 24 VAC / 60 Hz Electrical Ratings (Vac) 24 Vac Frequency (Hz) 60 Hz Temperature Ratings (max. ambient)(C) -40 C to +79 C Temperature Ratings (max. ambient)(F) -40 F to +175 F