____________________   >   Abingdon   >   System components   >   Basler AVC63-4 automatic voltage regulator avr

Basler AVC63-4 automatic voltage regulator avr


BASLER ELECTRIC AVC63-4 AUTOMATIC VOLTAGE REGULATOR (AVR)
Maximum Continuous: 4 Adc at 63 Vdc (252 W)
One Minute Forcing: 7 Adc at 100 Vdc (700 W) with 240Vac power input
Range: 190 - 240 Vac, 10%, single-phase
190 to 240 Vac, single-phase, 50/60 Hz, 10%, common with ac power input
Better than 1.0%, no-load to full-load
Less than 1.5 cycles for 5% changes is sensing voltage
Internal electromagnetic interference (EMI) filtering
Field voltage shuts down after time delay if exciter field voltage exceeds 100 Vdc, 5%. (See Overexcitation Shutdown for inverse time delay curve and description.)
Automatic voltage buildup occurs for residual generator voltages as low as 6 Vac.
Operating: 40 to 140 F ( 40 to 60 C)
Storage: 85 to 185 F ( 65 to 85 C)
27 to 52 Hz: 0.036 inches, double-amplitude
Withstands up to 20 G in each of three mutually perpendicular axes.



Basler AVC63-4 automatic voltage regulator avr